Reference Standards
Model |
SQW262L5/SQW262L10 /SQW262L15 |
SQW420L5/SQW420L10 /SQW420L15 |
SQW1000L5/SQW1000L10 /SQW1000L15 |
SQW2400L5/SQW2400L10 /SQW2400L15 |
||
Volume |
262 |
420 |
1000 |
2400 |
||
(mm) Internal size |
W |
700 |
700 |
1000 |
1300 |
|
H |
750 |
750 |
1000 |
1300 |
||
D |
500 |
800 |
1000 |
1400 |
||
Temperature range |
-70℃~+150℃ |
|||||
Humidity range |
20%RH~98%RH/(20~85℃) |
|||||
Temperaure fluctuation |
±0.5℃ |
|||||
Temperature dviation |
±2℃ |
|||||
Humidity deviation |
±3.0%RH(≧ 75%); ±5.0%RH(≦ 75%) |
|||||
Temperature chanqe rate |
5/10/15℃ min(Linear / nonlinear) |
|||||
Range of temperature change rate |
-55℃ ~+85℃ /-40℃ ~+85℃ |
|||||
Material |
Shell |
Double-side electrolysis steel plate SECC and surface spraying plastics |
||||
Inner shell |
SUS304/2B(fog surface)stainless steel plate |
|||||
Thermal insulation |
Hard polyurethane foam+ultra-fine glass fiber |
|||||
Regulator |
Heater |
Nicochrome fin heating wire heater |
||||
Humidifier |
Stainless steel armored heater(external humidifying) |
|||||
Fan |
Rear fan |
|||||
Refrigerating fluid |
Mechanical compressor |
|||||
Refrigerating fluid |
R404a /R23 |
|||||
Refrigerating mode |
Mechanical binary cascade refrigeration mode |
|||||
Controller |
Display |
Above 7.0 inch, TFT color LCD display |
||||
Operation mode |
Program operation, fixed value operation |
|||||
Setting mode |
Chinese menu, input by touch screen |
|||||
Progarm capacity |
Number of editable program: 99 maximum; step: 999 steps; cycle number: 99maximum |
|||||
Setting mode |
Temperature: adjust according to the temperature range of the equipment(upper limit: +5℃ ; lower limit: -5℃ ); humidity: 0%RH-100%RH
|
|||||
Display resolution |
Temperature: 0.01℃ ; time: 0.1min; humidiy; 0.1%RH(temperature and humidity test equipment) |
|||||
Input |
Thermal resistance |
|||||
Communication function(purchasing) |
RS-485 interface with local and remote communication function, monitoring software, RS-485/RS-232 convertor, one COM interface and one
|
|||||
Control mode |
Anti-integration saturation PID |
|||||
Curve recording function |
RAM with battery protection: it can save the setting value, sampling value and sampling time of equipment; and the maximum recording
|
|||||
USB function |
It is equipped with one U-disk and software disk special for PC computer(applicable for complex Chinese, English WINDOWS operation system); the test program is compiled by PC special software and saved in U-disk; and then the test program is tuned out from the U-disk and saved in the controller; or the program in the controller is saved in U-disk and then it is saved in PC machine to be analyzed and managed.The test curve data saved in the controller can be saved in U-disk.The test data/curve is directly printed and displayed by PC special software; or the recorded data is converted to access data file read by Microsoft Office.The test curve data recorded by the recorder is as follows: two-circuit temperature-setting temperature and actual temperature; two-circuit humidity-setting humidity and actual humidity(if the equipment has humidit function); record the time. |
|||||
Auxiliary function |
Fault alarm and reason, treatment prompt function, power failure protection function function, and upper and lower temperature limit protection functon;
|
|||||
water supply |
Water supply mode |
Lifting by water pump |
||||
Water storage tank |
Drawer water tank(self-control) |
|||||
Water quality |
Resistance rate ≥500Ωm |
|||||
Power |
AC380V±10%V 50HZ three-phase four-wire+protection ground wire |
|||||
Standard configuration |
One 360mm×440mm of electric heating anti-condensation hollow glass observation window; one left and right wire hole; two sample racks; floodlight; time accumulator(internal), one power cable(3m long), one sample control terminal, one RS-485/232 interface, one USB interface and one U-disk. |
|||||
Safety device |
Refrigerating system: over-voltage of compressor, over-heating of compressor, over-current of compressor motor, water supply and under-voltage of cooling water supply and under-voltage of cooling water(water cooling)
|