Autoclave
YYK 500 / YYK 750 / YYK 800 / YYK 900
An autoclave is a machine used to carry out industrial and scientific processes requiring elevated temperature and pressure in relation to ambient pressure/temperature.
YYK Series is a standard type Autoclave used for removing the residual air bubbles after affixing polarizer in LED production.
Applications
- Flat Panel Display Industry
No temperature overshoot.
Precision temperature uniformity available.
Adjustable air suction and exhaust speed.
Customized chamber dimensions.
4 step working procedures:
(1) Preheat: temperature rising, no pressurizing
(2) Pressurizing: holding temperature, pressurizing
(3) Deaeration: holding temperature, deaerating
(4) End: temperature cooling, pressure dropping
Safety features:
Door open / close detection, door lock / unlock detection, higher pressure alarm, air inlet pressure detection, safety valve, independent overheat protector, ELB to prevent over-current.
Technical specifications
YYK500 | YYK750 | YYK800 | YYK900 | |
Method | Heating + pressurizing | |||
Specifications | Class-1 pressure container (AQSIQ pressure container verification) | |||
Operating temperature range | Room temp. 10~70°C | |||
Operating pressure range | 0.101~0.9MPa | |||
Temperature distribution accuracy | ±3°C (at 50°C) | |||
Max. temperature reaching time | Within 15min (adjustable) | |||
Max. pressure reaching time | Within 20min (adjustable) | |||
Max. operating pressure | 0.9MPa | |||
Hydraulic test pressure | 1.35MPa | |||
Material | SUS304 stainless steel, internal polishing | |||
Air suction port | 15A (internally equipped with air filter and oil mist separator) | |||
Air exhaust port | 20A (manual and auto exhaust, equipped with silencer) | |||
Medium | Dry air (pressure: working pressure +0.05MPa or higher) | |||
Opening / closing system | Manual clutch easy to operate | |||
Temperature control system | PID control | |||
Stirring system | Stirred by centrifugal fan (Water-Cooling is not required for shaft seal, free-maintenance) | |||
Pressurizing system | Controlled by pressure controller | |||
Control system | PLC control | |||
Timer | Time range: 99 hr 59min, Digital setting and display | |||
Sensor | 5 groups of K thermocouple output terminals | |||
Pressure gauge | Pressure range: 0 to 1.0MPa, accuracy: ±1% (with upper limit alarm contact) | |||
Temp. controller | Digital setting and display, PID control | |||
Pressure controller | Digital setting and display, ON/OFF control | |||
Safety device | Door open / close detection, door lock / unlock detection, higher pressure alarm, air inlet pressure detection, safety valve, motor overheating protection, independent overheat protector, ELB to prevent over-current | |||
External dimensions WxDxH | 1000×1656×1546 mm | 1200×1957×1781mm | 1250×2057×1806 mm | 1400×1950×2232 mm |
Internal capacity | 850L | 1100L | 1100L | 1300L |
Power supply (50/60 Hz) | 3 phase AC380V 7A | 3 phase AC380V 8A | 3 phase AC380V 9A | 3 phase AC380V 12A |
Weight | ~700kg | ~900kg | ~1000kg | ~1300kg |
Thank you!