Applications
- Pharmaceutical Industry
- Microbiological Culture Research
- Cell Culture Research
- Industrial Products
DE & DT Series - Cleanroom Oven
DE411 / DE611 / DT411 / DT611
Laboratory Oven is essential for general heating routines from drying food samples to curing microchips. Lab Oven is one of the fundamental instruments every laboratory should have.
DE & DT Series Class 100 forced convection cleanroom ovens feature advanced temperature control and uniformity for temperature testing in a dust-free environment. Rely on the DE & DT mechanical clean room ovens to carry out unmatched drying, sterilization, or any heating applications that require a temperature range of up to 360°C.
Improved visibility and operability with its V type controller.
Displays power consumption, CO2 emissions and heater manipulated variables on the control panel.
Adopts anti-fouling casters which prevents wheel contamination during transportation.
Improved visibility of HEPA filter replacement timing by three color indication.
Lower equipment height compared to previous models (DE/DT411 approximately ~200 mm shorter).
Larger cable port from φ30mm to φ33mm.
Improved optional accessories and more customization options.
Displays power consumption, CO2 emissions and heater manipulated variables on the control panel.
Adopts anti-fouling casters which prevents wheel contamination during transportation.
Improved visibility of HEPA filter replacement timing by three color indication.
Lower equipment height compared to previous models (DE/DT411 approximately ~200 mm shorter).
Larger cable port from φ30mm to φ33mm.
Improved optional accessories and more customization options.
Safety features:
Enhanced safety with its phase-reversal relay detecting incorrect power source at installation.
Technical specifications
DE411 | DE611 | DT411 | DT611 | |
System | Forced air circulation | |||
Operating temperature range | Room temperature +30 to 260°C | Room temperature +30 to 360°C | ||
Temperature control accuracy | ±0.3°C at 260°C | ±0.3°C at 360°C | ||
Temp. fluctuation | ±0.5°C at 260°C | ±0.5°C at 360°C | ||
Temp. distribution accuracy | ±2.5°C at 260°C | ±4.0°C at 360°C | ||
Temp. gradient | ±10.0°C at 260°C | ±20.0°C at 360°C | ||
Max. temp. reaching time | ~70 mins. | ~80 mins. | ||
Interior | Stainless steel | |||
Exterior | Cold rolled steel plate with melamine resin baking finish | |||
Cable hole | 33mm×1 (right side) | |||
Exhaust port | 61mm | |||
Differential pressure meter | Analog type (0 ~ 300Pa) | |||
Heater | Stainless pipe heater | |||
Heat insulation material | Glass wool | |||
Heater Circuit Control | Triac zero-cross control | |||
Fan Type / Fan Motor | Sirocco fan, Condenser motor 400W | |||
Door | Single swing (left side) | |||
Door switch | Door open: fan motor and heater circuit off, Door close: fan motor and heater circuit on | |||
Filter | Heat resistant HEPA filter (dust-collection efficiency >99.97% up to 0.3μm particle filtering) | |||
Caster wheels / adjuster | Free swivel caster wheels without stopper / level adjuster (2 at front) | |||
Sensor | K-thermocouple double sensor (for temperature control and independent overheat prevention device) | |||
Temperature control | PID V control by microprocessor | |||
Temperature setting | Digital setting with ▲▼ keys | |||
Temperature display | Green 4 digit LED digital display (top screen) and orange 5 digit LED digital display (bottom screen) (1°C resolution) | |||
Other indications | LED indicates temperature patterns for heating/stabilizing/cooling | |||
Timer / timer resolution | 1 min. and 99 Hrs. 59 mins: duration operation, 24 hour setting: time operation | |||
Operation function | Constant temperature operation, Programmed operation (Maximum 99 steps, up to 99 patterns, repeat operation function), Duration/time select operation function (auto start/auto stop/quick auto stop, program operation) | |||
Additional functions | Variable fan speed, Accumulated on time, operation time function (up to 65,535 hours); calibration offset; accumulated power consumption monitoring, total CO2 emission monitoring, heater output monitoring; power recovery; setting data save and restore | |||
Safety device | Self-diagnostic functions (Detection for Temp. Sensor Failure, Triac Short Circuit, Automatic overheating prevention, Fan motor failure detection, Heater Line Disconnect, Main Relay Contact Damage), Earth leakage breaker, Key Lock Function, Independent overheating prevention device, Phase reversal relay, Door switch | |||
Earth leakage breaker | 15A | 20A | ||
Leak Current/Short Circuit/Over-current Protection, Rated Current Sensitivity 30mA | ||||
Internal dimensions WxDxH | 450×450×450 mm | 600×600×600 mm | 450×450×450 mm | 600×600×600 mm |
External dimensions WxDxH | 700×1025×1570 mm | 850×1175×1720 mm | 700×1025×1570 mm | 850×1175×1720 mm |
Internal capacity | 91L | 216L | 91L | 216L |
Shelf load capacity | ~30 kg/pc. | |||
Shelf rest step number / pitch | 12 steps / 30 mm | 17 steps / 30 mm | 12 steps / 30 mm | 17 steps / 30 mm |
Power supply (50/60 Hz) | 7A (no plug, round terminal) | 10A (no plug, round terminal) | 14A (no plug, round terminal) | |
Weight | ~200kg | ~270kg | ~200kg | ~270kg |
Shelfs and Brackets (stainless) | 2 pcs. / 4 pcs. | 3 pcs. / 6 pcs. | 2 pcs. / 4 pcs. | 3 pcs. / 6 pcs. |
Related products